PART 1 - GENERAL

1.1 SECTION INCLUDES

  1. Noise-reducing impact insulation systems for Wood Flooring, Laminate, Carpet and Tile.

1.2 RELATED SECTIONS

  1. Section 09 64 00 - Wood Flooring
  2. Section 09 62 19 - Laminate
  3. Section 09 30 00 - Tile Setting

1.3 REFERENCES

  1. U.S. Department of Housing and Urban Development (HUD): Guide to Airborne, Impact and Structure Borne Noise Control in Multi-famiy Dwellings.
  2. American Society of Testing and Materials (ASTM)
    1. ASTM D5116 Standard Guide for small-scale environmental chamber determinations of Organic Emissions for Indoor Material/Products.
    2. ASTM C627 Standard Test Method of Evaluating Ceramic Tile Installation Systems using the Robinson-Type Floor Test.
    3. ASTM E1007 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission through Floor-Ceiling Assemblies and Associated Support Structures.
    4. ASTM E2179 Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission through Concrete Floors.
    5. ASTM F1869 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor using Anhydrous Calcium Chloride.
  3. Leadership in Energy and Environmental Design - LEED®.
    1. LEED is an internationally recognized green building certification system, providing third-party verification that a building or community was designed and built using strategies aimed at improving performance across all the metrics that matter most: energy savings, water efficiency, CO2 emissions reduction, improved indoor environmental quality, and stewardship of resources and sensitivity to their impacts.

1.4 SYSTEM DESCRIPTION

  1. Performance Requirements: Provide recycled rubber resilient underlayment padding, which has been manufactured and installed to maintain performance criteria stated by manufacturer without defects, damage or failure..

1.5 SUBMITTALS

  1. Submit under provisions of Section 01300.
  2. Product Data: Manufacturer's data sheets on each product to be used, including:.
    1. Installation Instructions.
    2. LEED Documentation.
  3. Selection Samples: For each product specified, two samples will be provided for approval.

1.6 QUALITY ASSURANCE

  1. Manufacturer's Qualifications: The manufacturer shall be a firm with a minimum of four years of successful experience in manufacture of products with similar requirements
  2. Installer Qualifications: The installer shall be a firm with a minimum of two years of successful experience in installation of products with similar requirements.

1.7 DELIVERY, STORAGE AND HANDLING

  1. Store products in manufacturer's unopened packaging in a clean dry environment, until ready for installation.
  2. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.8 PROJECT CONDITIONS

  1. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

PART 2 - PRODUCTS

2.1 SUPPLIER

  1. Primary Acoustics LLC, 2801 Sisson Street, Baltimore, MD 21211-2902. Tel: 410338.1122. Fax: 410.338.1124. Toll free: 866.388.8833. Web site: www.primaryacoustics.com
  2. Substitutions: Not permitted.
  3. Requests for substitutions will be considered in accordance with provisions of Section 01600.

2.2 PRODUCT

  1. VerdeX 3mm-20mm recycled rubber Acoustical Floor Underlayment Impact Sound Insulation supplied by Primary Acoustics LLC.

2.3 NOISE-REDUCING IMPACT INSULATION SYSTEM FOR WOOD FLOORING, LAMINATE, CARPET, CERAMIC TILE FLOORING

  1. Acceptable Product: VerdeX®
    1. Physical Characteristics:
      • Made from 100% recycled SBR (Styrene-Butadien Rubber) tire rubber.
      • 3mm -20mm
      • 48 inches wide rolls
      • Material Weight 1.8 lb/ft2

PART 3 - EXECUTION

3.1 EXAMINATION

  1. Do not begin until substrates have been properly prepared.
  2. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

  1. Clean surfaces thoroughly prior to installation.
  2. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

  1. Install in accordance with manufacturer's instructions.

3.4 PROTECTION

  1. Protect installed products until completion of project.
  2. Touch-up, repair or replace damaged products before Substantial Completion..

END OF SECTION

Download the VERDEX specification in Adobe Acrobat Reader PDF Format.

 

Call The Doctor
866-388-8833

2400 Sisson Street
Baltimore, Maryland
U.S.A. 21211-2903
410-338-1122
Fax: 410-338-1124

 

  Swirnow Building Systems is service mark used under license.
The affiliates of Swirnow Building Systems and Primary Acoustics LLC are separate and independent legal entities.
No dealer or affiliate is responsible for the services or activities of any other dealer or affiliate. Read our Disclaimer.
Copyright © 2006- 2019. Primary Acoustics LLC. All Rights Reserved.